Air Cooled Modular Chiller 35-2240 kW
Modular Design with Demand-Matched Efficiency, T3 55°C Climate Class, Low GWP Ready
Energy Consumption That Tracks Occupancy
Eliminate structural inefficiency with modular chillers that scale capacity in direct proportion to actual building demand. Unlike oversized HVAC systems that waste 20-30% more energy per ton of cooling, our modular approach ensures each module operates independently at its optimum efficiency point.
At partial building loads, fewer modules run—and those that run operate at or near full capacity where efficiency is highest. This fundamentally differs from single large chillers that must cycle down to low loads where efficiency drops dramatically.
Key Features
Right-Sized Energy Consumption
Install only the modules needed for current load, adding capacity as building occupancy grows. Each module runs at its design-point efficiency (75-100% load range) where IEER ratings are most favorable.
- Capacity matches actual load—no oversized baseline energy consumption
- Each module runs near peak efficiency in the 75-100% load sweet spot
- Eliminates chronic part-load waste from single large chillers
- Scalable energy baseline that grows proportionally with occupancy
- Accurate energy benchmarking across portfolio properties
- Lower Scope 2 emissions from day one
Low-GWP Refrigerant Options
Multiple refrigerant options to match regulatory environment and ESG targets with compliance through 2030 and beyond.
- R290 (GWP 3)—lowest-GWP commercial chiller option available
- R452A (GWP 139)—93% reduction vs. R410A, F-Gas compliant
- R513A (GWP 631)—56% reduction vs. R134a, drop-in compatible
- Regulatory compliance mapped for EU, US, Middle East, and Asia
- Future-proof procurement with low-GWP options available now
- ESG disclosure ready with quantifiable GWP data
T3 55°C Climate Performance
Full rated capacity at 55°C ambient ensures consistent energy performance across all climate zones without derating.
- Consistent energy performance globally—no climate-dependent derating
- Accurate carbon modeling with nameplate efficiency equal to delivered efficiency
- Portfolio benchmarking simplified with same baseline across all properties
- No hidden energy penalties—what you spec is what you measure
- Reliable in extreme heat events when cooling is most needed
- Simplified reporting with one efficiency standard for all properties
BMS Integration for Energy Monitoring
Native Modbus RTU, Modbus TCP/IP, and BACnet IP connectivity enables seamless integration with building energy management systems.
- Per-module energy metering for granular consumption visibility
- Standard protocols integrate with any BEMS
- ISO 50001 audit-ready data with verified energy consumption records
- GHG Protocol Scope 2 ready for carbon calculations
- ESG disclosure support for GRI, CDP, and TCFD reporting
- Performance gap detection to identify underperforming units
Oil-Free Operation Options
Minimal oil charge and oil-free design features eliminate contamination risk for air quality sensitive environments.
- Minimal oil charge reduces environmental liability
- No oil disposal requirements lower waste management costs
- Cleaner heat exchange without oil film degradation
- Sustained rated efficiency with no oil-fouling degradation
- Simpler environmental reporting with less hazardous waste
- Lower lifecycle environmental impact over 20+ years
20+ Year Design Life
Long operational horizon maximizes carbon payback and maintains consistent performance throughout the lifecycle.
- 20+ year service life maximizes embodied carbon amortization
- Sustained efficiency over lifecycle with no progressive degradation
- Module-level replacement without full-system disposal
- Predictable lifecycle emissions with accurate 20-year projections
- Lower lifecycle carbon intensity through efficient operation
- Circular economy alignment with individual module recyclability
Technical Specifications
| Cooling Capacity |
35-2,240 kW (single circuit) |
| Heating Capacity |
Available (heat pump models) |
| Refrigerant Options |
R410A (GWP 2,088) / R452A (GWP 139) / R290 (GWP 3) / R134a (GWP 1,430) / R513A (GWP 631) |
| Platform Options |
Midea Series / Climaveneta Series / A.W.S. Series |
| Climate Class |
T3—Full capacity at 55°C ambient |
| Voltage |
200-440V, 50/60Hz |
| Certifications |
CE, Eurovent, AHRI 550/590 |
| BMS Protocols |
Modbus RTU, Modbus TCP/IP, BACnet IP |
| Installation |
Rooftop outdoor |
| Warranty |
5 years |
Ideal Applications
Green-certified buildings
Portfolio energy optimization
Regulated markets
Net-zero carbon targets
Hospital and healthcare
Educational campuses
Mixed-use developments
Data centers
Government buildings
ESG-focused portfolios
Certifications & Standards
CE Certification
Eurovent Certification
AHRI 550/590
ISO 9001/14001/45001
Product Images